Identification
A:
Ultraviolet Absorption
197U
Spectral range:
300 to 700 nm.
Solution
Prepare as directed for the Test solution in the test for Content of total carotenoids.
Ratio:
A446 / A474, between 1.09 and 1.14.
B:
The retention time for the major peak in the chromatogram of the Test solution corresponds to that in the chromatogram of the Standard solution, as obtained in the test for Content of lutein.
Zeaxanthin and other related compounds
[noteUse low-actinic glassware.
]
Solvent, Mobile phase, Standard solution, Test solution, and Chromatographic system
Proceed as directed under Content of lutein.
Procedure
Inject a volume (about 10 µL) of the
Test solution into the chromatograph, record the chromatogram, and measure the peak responses. The peak area of zeaxanthin is not more than 9.0% of the total detected area of peaks in the chromatogram of the
Test solution. Calculate the percentage of zeaxanthin in the portion of Lutein taken by the formula:
T(ri / rs)
in which
T is the content, in percentage, of total carotenoids as determined in the test for
Content of total carotenoids; ri is the individual peak response of zeaxanthin; and
rs is the sum of the responses of all the peaks: not more than 8.5% of zeaxanthin is found. Calculate the percentage of other related compounds in the portion of Lutein taken by the formula:
100(ri / rs)
in which
ri is the individual peak response of any other peak in the chromatogram (excluding zeaxanthin and lutein); and
rs is the sum of the responses of all the peaks: not more than 1.0% of any other single related compound is found.
Content of lutein
Solvent:
a mixture of hexanes, acetone, toluene, and dehydrated alcohol (10:7:7:6).
Mobile phase
Prepare a filtered and degassed mixture of hexane and ethyl acetate (75:25). Make adjustments if necessary (see
System Suitability under
Chromatography
621
).
Standard solution
Dissolve a suitable quantity of USP Lutein RS in Mobile phase to obtain a solution containing about 150 µg per mL.
Test solution
Transfer about 1 mL of Test stock solution from the test for Content of total carotenoids, and evaporate under a stream of nitrogen to dryness. Add 1 mL of Mobile phase, and sonicate to dissolve.
Chromatographic system (see Chromatography
621
)
The liquid chromatograph is equipped with a 446-nm detector and a 4.6-mm × 25-cm column that contains 5-µm packing L3. The flow rate is about 1.5 mL per minute. Chromatograph the
Standard solution, and record the peak responses as directed for
Procedure: the relative retention times are about 1.05 for zeaxanthin and 1.0 for lutein; the resolution,
R, between lutein and zeaxanthin is not less than 1.0; the tailing factor is not more than 2; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Inject a volume (about 10 µL) of the
Test solution into the chromatograph, record the chromatogram, and measure the peak area responses. The peak area of lutein is not less than 85.0% of the total detected area of peaks in the chromatogram. Calculate the percentage of Lutein taken by the formula:
T(ri / rs)
in which
T is the content, in percentage, of total carotenoids as determined in the test for
Content of total carotenoids; ri is the individual peak response of lutein in the
Test solution; and
rs is the sum of the responses of all the peaks: not less than 74.0% of lutein is found.
Content of total carotenoids
[noteUse low-actinic glassware.
]
Solvent:
a mixture of hexanes, acetone, toluene, and dehydrated alcohol (10:7:7:6).
Test stock solution
Transfer about 30 mg of Lutein to a 100-mL volumetric flask, and dissolve in and dilute with Solvent to volume.
Test solution
Quantitatively dilute the Test stock solution (1 in 100) with dehydrated alcohol to obtain a solution having a final concentration of about 3.0 µg per mL.
Procedure
Determine the absorbance of the
Test solution at the wavelength of maximum absorbance at about 446 nm, with a suitable spectrophotometer, using dehydrated alcohol as a blank. Calculate the percentage of total carotenoids as lutein (C
40H
56O
2) by the formula:
10,000A / 2550W
in which
A is the absorbance of the
Test solution; W is the weight, in g, of Lutein taken to prepare the
Test stock solution; and 2550 is the absorptivity of the lutein in alcohol.