n-Octadecane,

CH
3(CH
2)
16CH
3
254.49


[
593-45-3]Use a gas chromatographic standard with a content of not less than 99.5%.
Octadecyl Silane



[
18623-11-5]This reagent is formed
in situ by reaction of the column support with a suitable silylating agent such as octadecyl trichlorosilane.
Octanesulfonic Acid Sodium Salt
(Sodium 1-octanesulfonate),

C
8H
17NaO
3S·H
2O
234.29 


[
5324-84-5]Use a suitable grade with a content of not less than 99.0%.
Octanophenone,

C
14H
20O
204.31 


[
1674-37-9]Colorless liquid.
Assay
mobile phase
Prepare a filtered and degassed mixture of acetonitrile and water (7:3).
procedure
Inject about 20 µL into a suitable liquid chromatograph (see
Chromatography
621
) equipped with a 254-nm detector and a 4.6-mm × 15.0-cm column that contains packing L1. The flow rate is about 2 mL per minute. The area of the C
14H
20O peak is not less than 99% of the total peak area.
Octoxynol 9
See Nonionic Wetting Agent.
(p-tert-Octylphenoxy) nonaethoxyethanol,

C
34H
62O
11
646.85Use a suitable grade.
[noteA suitable grade is available commercially as Tergitol Nonionic NPX, and as Triton N101, from reagent suppliers.]
(p-tert-Octylphenoxy)polyethoxyethanol
Use a suitable grade.
[noteA suitable grade is available commercially as Triton 100 from reagent suppliers.]
Octyl Sulfate, Sodium Salt,

C
8H
17O
4SNa
232.27White powder.
Solubility
A 2-g portion dissolves in 100 mL of water.
Olefin Detector Tube
A fuse-sealed glass tube so designed that gas may be passed through it and containing suitable absorbing filters and support media for the indicator in a stabilized form of permanganate.
Measuring range:
0.06 to 3.2 Vol.% Propylene, 0.04 to 2.4 Vol.% Butylene.
Oligo-deoxythymidine
Polymeric length: 18. Use a suitable grade.
Orange G
(the sodium salt of azobenzene-betanaphthol disulfonic acid),

C
6H
5N:NC
10H
4(OH)(SO
3Na)
2-2,6,8
452.37 


[
1936-15-8]Orange to brick-red powder or dark red crystals. Readily soluble in water, yielding an orange-yellow solution; slightly soluble in alcohol; insoluble in ether and in chloroform. The addition of
tannic acid TS to its 1 in 500 solution causes no precipitation
(acid color). The addition of hydrochloric acid to a mixture of 500 mg of zinc dust and 10 mL of its 1 in 500 solution produces decolorization. When filtered, the colorless filtrate, on standing exposed to air, does not regain its original color
(presence of azo-group). When heated, orange G does not deflagrate (distinction from
nitro colors). The addition of barium or calcium chloride TS to a concentrated solution of orange G produces a colored, crystalline precipitate. The addition of hydrochloric acid to its 1 in 500 solution produces no change; the addition of
sodium hydroxide TS to a similar solution produces a yellowish red to a Bordeaux color but no precipitation. Orange G dissolves in sulfuric acid with an orange to yellowish-red color. No change in color results upon diluting the solution cautiously with water.
Orcinol
(5-Methylresorcinol),

C
7H
8O
2·H
2O
142.15 


[
6153-39-5]White to light tan crystals.
Assay
Transfer about 60 mg, accurately weighed, to a 100-mL volumetric flask, dissolve in methanol, dilute with methanol to volume, and mix. Transfer 5.0 mL of this solution to a 50-mL volumetric flask and dilute with methanol to volume, and mix. Using a suitable spectrophotometer, 1-cm cells, and methanol as the blank, record the absorbance of the solution at the wavelength of maximum absorbance at about 273 nm. From the observed absorbance, calculate the absorptivity (see
Spectrophotometry and Light-scattering
851
): the absorptivity is not less than 13.2, corresponding to not less than 98% of C
7H
8O
2·H
2O.
Orthophenanthroline
See 1,10-Phenanthroline.
Osmium Tetroxide
(Osmic Acid; Perosmic Anhydride),

OsO
4
254.23 


[
20816-12-0]Use ACS reagent grade.
Oxalic Acid,

H
2C
2O
4·2H
2O
126.07 


[
6153-56-6]Use ACS reagent grade.
3,3¢-Oxydipropionitrile,

O(CH
2CH
2CN)
2
124.14 


[
1656-48-0]Clear, colorless to slightly yellow liquid. Refractive index: about 1.446 at 20

.
Boiling range:
between 174

and 176

at 10 mm of mercury.
Oxygen-Helium Certified Standard
A mixture of 1.0% oxygen in industrial grade helium. It is available from most suppliers of specialty gases.